Portable
Networking Protocol Analyzers and
Datacom BERT Family
Our Network
Testing Equipment includes a variety of portable
testing equipment for networking professionals.
Our HCT Series testers are menu
driven protocol analyzers with industry standard
interfaces such as V.35, X.21, RS-530/449/232,
sync or async. They provide protocol analysis
of ASYNC, SYNC(BSC), HDLC, SDLC, X.25, DDCMP,
Frame Relay, SNA, PPP, SLIP, V5.1, V5.2, ISDN-D
and SS7 as well as BERT (Bit Error Rate Testing)
functions.
Our Datacom BERT testers (HCT-BERT)
are menu driven data communication testers similar
to our HCT Series but with BERT
functions only. They provide a wide range of testing
patterns and operate as a pattern generator and/or
receiver. |
Model
: HCT-7000
Model : HCT-6000
Model : HCT-6000A
Model : HCT-BERT/128K
Model : HCT-BERT/2M
Model : HCT-2000E
|
 |
The
HCT Series of notebook sized communications
testers are communication protocol and/or BERT
(Bit Error Rate Test) analyzers that provide a
wide range of protocol communications, suitable
for equipment installations, on-line or off-line
diagnostics, debugging, and interface development.
All HCT Series feature backlit Liquid
Crystal Displays, tactile membrane switch keyboards,
interface lead indicator LEDs, and internal rechargeable
batteries. Included with the HCT-7000 or
HCT-6000 is a CDROM with both DOS and
Windows based monitor programs, a comprehensive
User's Guide, universal AC power adapter (100
to 240VAC), and a sturdy zippered carvas carry
case. A full assortment of interface adapter cables
and adapters are available for a wide range of
interface standards.
|
| Quick Comparison Table of FUNCTIONS for the
HCT Series |
| FUNCTIONS |
HCT-2000E
|
HCT-
BERT/2M
|
HCT-
BERT/128
|
HCT-6000A
|
HCT-6000
|
HCT-7000
|
| Master Protocol Analysis
|
*
|
|
|
*
|
*
|
*
|
| Firmware ROM upgrade |
|
*
|
*<
td>
|
*
|
*
|
|
| Flash upgrade |
|
|
|
|
|
*
|
| Auto Configuration |
*
|
|
|
*
|
*
|
*
|
Examine captured
data, files, clocks |
*
|
|
|
*
|
*
|
*
|
| ASYNC Terminal |
*
|
|
|
*
|
*
|
*
|
| ASYNC Scan |
*
|
|
|
*
|
*
|
*
|
| File Manager |
*
|
|
|
*
|
*
|
*
|
| Remote Control |
|
* |
*
|
*
|
*
|
*
|
| Up/Download to PC |
*
|
|
|
*
|
*
|
*
|
| Expansion PC Card memory
|
|
|
|
|
|
*
|
| On-line Monitor on PC
|
|
|
|
*
|
*
|
*
|
| Self Test & Diagnostics
|
*
|
* |
*
|
*
|
*
|
*
|
| 128K BERT Analysis |
|
* |
*
|
*
|
*
|
*
|
| 2M BERT Analysis |
|
* |
|
|
*
|
*
|
| TCP/IP Option |
|
|
|
*
|
*
|
*
|
| Frame Relay Option |
|
|
|
*
|
*
|
included
|
| SNA Option |
|
|
|
*
|
*
|
*
|
| G.821/G.826 2M BERT
Option |
|
*
|
|
|
*
|
*
|
| RS-232 Interface |
*
|
*
|
*
|
*
|
*
|
*
|
| RS-449/530, X.21 Interface
|
|
*
|
*
|
*
|
*
|
*
|
| G.703 E1, T1 Interface
|
|
|
|
|
|
*
|
| G.703/64K Interface
|
|
|
|
|
|
*
|
| G.703 External Interface
|
|
* |
*
|
*
|
*
|
|
| Round trip delay measurement |
|
|
|
|
|
*
|
| SLIP measurement |
|
|
|
|
|
*
|
| Datacom clock measurement |
|
|
|
|
|
*
|
| Signal frequency measurement |
|
|
|
|
|
*
|
| External Drop&Insert |
|
|
|
|
|
*
|
| Alarm/Loop setting and
monitor |
|
|
|
|
|
*
|
| Signaling/Timeslot set/display |
|
|
|
|
|
*
|
| User Patterns |
|
|
|
|
|
*
|
| SA bit set/display |
|
|
|
|
|
*
|
| HCT Series of Protocol / BERT Analyzers
|
| The
HCT-7000, flagship
model of the HCT Series, provides WAN protocol
analysis for ASYNC, SYNC (BSC), HDLC, SDLC, X.25,
SNA, DDCMP, TCP/IP, PPP, SLIP and Frame Relay
communications at full E1 transmission speeds
(2.048Mbps), plus 2M (2.048Mbps) BERT (Bit Error
Rate Testing). The basic unit supports two hardware
interface modules that can be any pair supporting
RS-232C (V.24/V.28), RS-530, V.35, RS-449 (V.36),
X.21, G.703 E1, G.703 T1(DS1), or G.703/64K Co-directional.
The HCT-6000 model includes protocol analysis for ASYNC, SYNC(BSC), HDLC, SDLC,
X.25, DDCMP, TCP/IP, PPP, SLIP and Frame Relay
communications. The HCT-6000 is
capable of two modes of BERT testing. Low speed
BERT is supported at speeds up to 128Kbps, while
high speed BERT supports speeds at up to 2.048Mbps.
The hardware interfaces supported include RS-232C,
V.35, X.21, and RS-449.
The
HCT-6000A model includes
all the features of the HCT-6000
with the exception of high speed (2M) BERT.
The HCT-BERT/2M model provides 2M (E1 and
T1 speed) and 128K BERT only, without any protocol
analysis.
The HCT-BERT/128 model provides only 128K
BERT capability without any protocol analysis.
The HCT-2000E model includes
protocol analysis for ASYNC, SYNC(BSC), HDLC,
SDLC, and X.25 Frame and Packet plus BERT at
speeds up to 72Kbps. The hardware interfaces
supported include RS-232 (V.24/V.28) and V.35.
|
| General Specifications of HCT Series
|
| *Basic
Interfaces |
RS-232C/D(V.24),
RS-449(V.36), RS-530, X.21, V.35, Centronics Printer
port, and Remote control port (other optional
interface modules available for the HCT7000) |
| *Protocols
|
ASYNC,
SYNC(BSC), HDLC, SDLC, X.25, DDCMP (Sync) |
| *Optional
|
Frame
Relay, SNA, TCP/IP, PPP, SLIP |
| *Data
Rate |
ASYNC:
50-115,200bps (HCT-2000 up to 72,000bps)
SYNC: 300-128,000bps (HCT-2000 up to 72,000bps)
HCT7000 up to 2048Kbps |
| *Data
Codes |
ASCII,
EBCDIC, HEX, IPARS, TRANSCODE, EBCD |
| *Data
Length |
ASYNC
Mode: 5,6,7, or 8 bits
SYNC Mode: 8 bits |
| *Parity
Bit |
ASYNC
Mode: None, Odd, Even |
| *Stop
bits |
ASYNC
Mode: 1, 1/2 , 2 |
| *Bit
Sending |
LSB
or MSB first |
| *Data
Polarity |
Normal
or Inverted |
| *Display
Modes |
Data
only; Full Duplex
Data only, Half Duplex
Data and Lead Status
Frame and Packet |
| *Error
Check |
None,
Parity, LRC, CRC-16, CRC-CCITT |
| *Status
LEDs |
Leads;
TD, RD, RTS, CTS, DSR, DTR, DCD, TC, RC, XTC (both
SPACE and MARK)
Interface; RS232, V.35, RS449, G.703
Emulation; DTE or DCE
External power; external adapter in use
Sync Loss
Battery low
I/F power; DC9V out RS232 I/F pin 9 is on |
| *LCD
Display |
8
lines, 32 characters per line, with backlight
and contrast controls
HCT7000 features 320x240 graphic display with
backlight and contrast controls |
| *Capture
Buffer |
512KB
static ram (256KB for HCT-2000) battery backed
up |
| *Line
Monitor |
DTE;
DCE; DTE & DCE |
| *Emulation |
DTE;
DCE; MONITOR only |
| *BERT
Patterns |
63,
511, 2047, FOX (ASCII), SPACE, MARK, ALT |
| *BERT
Speed |
2Mbps
(HCT-7000, HCT-6000 and HCT-BERT/2M)
128Kbps (all except HCT-2000)
72Kbps (HCT-2000) |
| *Counters
& Timers |
5
each internal counters and timers |
| *Power
Source |
AC100~240V
adapter to DC9V 600mA |
| *Physical
dimension |
237mm(L)
* 173mm(W) * 37mm(H) |
| *Weight |
1.1Kg
net |
| *Temperature |
0-50ºC
(32-125ºF) |
| *Humidity |
up
to 90% RH non-condensing |
| Specifications for 128Kbps BERT |
| *Mode |
DTE only |
| *Interface |
RS-232, V.35,
X.21, RS-449, RS-530 |
| *Data
Rates |
ASYNC:
50 to 115200 bps
SYNC: 150 to 128000 bps |
| *Tx
Patterns |
63,
511, 2047, FOX (ASCII), SPACE, MARK, ALT
|
| *Block
Size |
1000
bits or Pattern length |
| *Tx
Clock |
DTE
or DCE |
| *
Flow control |
Xon/Xoff
or CTS on |
| *
Flexible Printer Function |
| *
Test Duration |
10e3 to 10e8 bits
1 to 60 Minutes
Continuous |
| *
Tx Bit Count |
0 to
999999999, 1.0000e9 to 9.9999e12 |
| *
Rx Bit Count |
0 to
999999999, 1.0000e9 to 9.9999e12 |
| *
Tx Block Count |
0 to
999999999, 1.0000e9 to 9.9999e11 |
| *
Rx Block Count |
0 to
999999999, 1.0000e9 to 9.9999e11 |
| *
Rx Bit Error Count |
0 to
999999999, 1.0000e9 to 9.9999e12 |
| *
Rx Block Error Count |
0 to
999999999, 1.0000e9 to 9.9999e11 |
| *
Rx Bit Error Rate |
0 to
1.0e-13 |
| *
Error seconds |
0 to
99999999 |
| *
Forced Error Bit Count |
0 to
999999 |
|
|
| Specifications for High Speed (2M) BERT
|
| *
Mode |
DTE
or DCE |
| *
Interface |
RS-232
(max. up to 128Kbps)
V.35, X.21, RS-449, RS-530
G.703 (optional FE1/FT1 Pack)
|
| *
Data Rates |
(64K
multiples) |
|
|
48K,
64K, 128K, 192K, 256K, 320K, 384K, 448K,
512K, 576K, 640K, 704K, 768K, 832K, 896K,
960K, 1024K, 1088K, 1152K, 1216K, 1280K,
1344K, 1408K, 1472K, 1536K, 1544K, 1600K,
1664K, 1728K, 1792K, 1856K, 1920K, 1984K,
2048K |
|
|
(56K
multiples) |
|
|
56K,
112K, 168K, 224K, 280K, 336K, 392K, 448K,
504K, 560K, 616K, 672K, 728K, 784K, 840K,
896K, 952K, 1008K, 1064K, 1120K, 1176K,
1176K, 1232K, 1288K, 1344K, 1400K, 1456K,
1512K, 1544K, 1568, 1624K, 1680K, 1736K,
1792K |
| *
Tx Patterns |
63,
127, 511, 2047, 2e15-1, 2e20-1, QRSS,
2e23-1, MARK, SPACE, ALT, 11001100, 3
in 24, 1 in 16, 1 in 8, 1 in 4. |
| *
Tx clock source |
Internal,
Internal with the polarity of the output
clock inverted, External, External with
the polarity of the output clock inverted
|
| *
Rx clock source |
DPLL(Digital
Phase-Locked Loop), External, External
with the polarity of the output clock
inverted |
| *
Error insertion |
one
bit, 10e-1, 10e-2, 10e-3, 10e-4, 10e-5,
10e-6, 10e-7 |
| *
Flow control |
DCE
permitted to transmit on RTS signal or
not, DTE permitted to transmit on CTS
signal or not |
| *
Sync |
Loss
indicated by LED |
| *
Data Format |
Sync
|
|
| Common Analysis : |
| *
Rx Bit Count |
0
to 999999999,
1.0000e9 to 9.9999e14 |
| *
Rx Bit Error Count |
0
to 999999999,
1.0000e9 to 9.9999e14 |
| *
Forced Error Bit Count |
0
to 999999 |
| *
Bit Error Rate |
0
to 1.0e-15 |
| *
Sync Loss Seconds |
0
to 999999999 |
| *
Error Seconds |
0
to 999999999 |
| *
Error Free Seconds |
0
to 999999999 |
| *
Test duration |
1
min. to 60 min.
continuous |
|
| G.821 Analysis: |
| *
Available Seconds |
0
to 999999999 |
| *
% of Available Sec. |
0
to 100% |
| *
Degraded Minutes |
0
to 999999999 |
| *
% of Degraded Min. |
0
to 100% |
| *
Severely Erred Sec. |
0
to 999999999 |
| *
% of Severely Err. Sec. |
0
to 100% |
| *
G.821 Erred Sec. |
0
to 999999999 |
| *
% of G.821 Err. Sec. |
0
to 100% |
| *
Unavailable Sec. |
0
to 999999999 |
| *
% of Unavailable Sec. |
0
to 100% |
|
|
| Application of HCT-6000 with G703/FE1 Fractional
E1 Access Unit |
| Fig 1 BERT
Test on Fractional E1 |
|