Site Analyzer SA-2500A
Identify Small Problems
Before They Grow Into Big Headaches
Easy Op with Digital Power Me& Cable o-Use Easy-T-To-Use Cable ter Antenna
tion & Tester
Antenna Tester
The Site Analyzer's advanced design and high resolution color display help you detect minor problems before they become major headaches. Bird's instrument easily uncovers faults that elude less sophisticated testers. And the Site Analyzer's high directivity and

low source match ensure accurate and repeatable Match and Fault Location measurements.
o Locate long range problems with 238 display points
o Pinpoint small problems with 60 dB dynamic range
o High resolution marker reports VSWR with the precision of expensive laboratory equipment
o Perform cable insertion loss measurements
o Flash feature allows easy firmware upgrades via e-mail
High ambient RF levels can limit the usefulness of other cable and antenna test instruments.
World-wide applications include Cellular and PCS/DCS systems with AMPS, CDMA, GSM or TDMA modulation.
Other applications include, 3G, Microwave, Paging, Trunking, WLAN and WLL. Frequency Range is 780 to 2500 MHz
o Easy operation for first-time, occasional or experienced users
o Digital Power Meter Option compatible with Bird power sensors
o Accurate and repeatable measurements
o Immunity to on-channel interference (+13 dBm) for testing at co-located antenna sites
o High-resolution color display
o Fast sweep rate
o On-screen comparison of live sweep and recalled trace
o Unlimited trace overlays per report to compare antennas and track performance over time
New Digital Power Meter Option
o Display forward and reflected power as well as VSWR and return loss.
o Compatible with Model 5010 Digital Power Sensor and DPM Elements
SPECIFICATIONS
Site Analyzer. Model SA-2500A
FREQUENCY CHARACTERISTICS
Frequency Range: 780 - 2500 MHz
Trace Resolution: 238 data points
MEASUREMENT
CHARACTERISTICS
Return Loss: 0 to -60 dB
Test Port: N-type female connector
Impedance: 50 .
Speed: 1 multi-frequency scan/4 seconds
Immunity to Interfering Signals: Rejects on-channel signals up to +13 dBm.
Maximum Input Signal: +22 dBm
PERIPHERAL PORTS
Data transfer: 9-pin RS-232 (DB9),
compatible with PC serial port.
Printer: 25-pin (DB25) parallel. Built-in driver.
POWER
Internal: Rechargeable (fast charge)
Li-Ion batteries.
3 hour minimum operating time.
Auto shut-off conserves battery life.
External DC: 9 to 16 Vdc, fused
External AC: 90 to 264 Vac @ 45-66 Hz
ENVIRONMENTAL
Operating Temperature: -10 to 50°C (14°C to 122° F)
Storage Temperature: -40°C to 80°C (-40°C to 176°F)
Humidity: 95%±5% max., (non-condensing)
Altitude: Up to 15,000 feet (4572 m)
FORM FACTOR
Dimensions: 10.5 x 8.5 x 3.2 inches
Weight: 5 lb (2 kg)
STANDARD ACCESSORIES
The Site Analyzer. includes Carrying Case, Instruction Manual, Serial Cable, PC Tool Software for Windows, AC Power Supply and Automotive Power Adapter.
BEC MODELNUMBER DESCRIPTION
SA-2500A SITE ANALYZER,780-2500MHZ
CAL-MN-A CALIBRATION COMBO, (M)N
CAL-FN-A CALIBRATION COMBO, (F)N
CAL-ME-A CALIBRATION COMBO, (M)7/16
CAL-FE-A CALIBRATION COMBO, (F)7/16
5010 DIGITAL POWER SENSOR
*DPM ELEMENTS ELEMENTS FOR DIGITAL POWER SENSOR
TC-MNMN-1.5 TEST CABLE, (M)N-(M)N, 1.5M
TC-MNMN-3.0 TEST CABLE, (M)N-(M)N, 3.0M
TC-MNMN-5.0 TEST CABLE, (M)N-(M)N, 5.0M
TC-MNFN-1.5 TEST CABLE, (M)N-(F)N, 1.5M
TC-MNFN-3.0 TEST CABLE, (M)N-(F)N, 3.0M
TC-MNFN-5.0 TEST CABLE, (M)N-(F)N, 5.0M
TC-MNFE-1.5 TEST CABLE, (M)N-(F)7/16, 1.5M
TC-MNFE-3.0 TEST CABLE, (M)N-(F)7/16, 3.0M
TC-MNFE-5.0 TEST CABLE, (M)N-(F)7/16, 5.0M
PA-MNME ADAPTER, (M)N-(M)7/16
PA-FNME ADAPTER, (F)N-(M)7/16
PA-MNFE ADAPTER, (M)N-(F)7/16
PA-FNFE ADAP TER, (F)N-(F)7/16
7002B870 TRANSIT CASE, SITE ANALYZER
SA-BATPAK BATTERY PACK, EXTERNAL
COMPATIBLE PRODUCTS
Model 5010 Digital Power Sensor and *DPM Elements
 
 
Beijing Lixingweiye Technology development Co.,Ltd