The Site Analyzer's advanced design and high resolution
color display help you detect minor problems before
they become major headaches. Bird's instrument easily
uncovers faults that elude less sophisticated testers.
And the Site Analyzer's high directivity and
|
 |
low
source match ensure accurate and repeatable Match
and Fault Location measurements.
o Locate long range problems with 238 display points
o Pinpoint small problems with 60 dB dynamic range
o High resolution marker reports VSWR with the precision
of expensive laboratory equipment
o Perform cable insertion loss measurements
o Flash feature allows easy firmware upgrades via
e-mail
High ambient RF levels can limit the usefulness of
other cable and antenna test instruments.
World-wide applications include Cellular and PCS/DCS
systems with AMPS, CDMA, GSM or TDMA modulation.
Other applications include, 3G, Microwave, Paging,
Trunking, WLAN and WLL. Frequency Range is 780 to
2500 MHz
o Easy operation for first-time, occasional or experienced
users
o Digital Power Meter Option compatible with Bird
power sensors
o Accurate and repeatable measurements
o Immunity to on-channel interference (+13 dBm) for
testing at co-located antenna sites
o High-resolution color display
o Fast sweep rate
o On-screen comparison of live sweep and recalled
trace
o Unlimited trace overlays per report to compare antennas
and track performance over time
New Digital Power Meter Option
o Display forward and reflected power as well as VSWR
and return loss.
o Compatible with Model 5010 Digital Power Sensor
and DPM Elements
SPECIFICATIONS
Site Analyzer. Model SA-2500A
FREQUENCY CHARACTERISTICS
Frequency Range: 780 - 2500 MHz
Trace Resolution: 238 data points
MEASUREMENT
CHARACTERISTICS
Return Loss: 0 to -60 dB
Test Port: N-type female connector
Impedance: 50 .
Speed: 1 multi-frequency scan/4 seconds
Immunity to Interfering Signals: Rejects on-channel
signals up to +13 dBm.
Maximum Input Signal: +22 dBm
PERIPHERAL PORTS
Data transfer: 9-pin RS-232 (DB9),
compatible with PC serial port.
Printer: 25-pin (DB25) parallel. Built-in driver.
POWER
Internal: Rechargeable (fast charge)
Li-Ion batteries.
3 hour minimum operating time.
Auto shut-off conserves battery life.
External DC: 9 to 16 Vdc, fused
External AC: 90 to 264 Vac @ 45-66 Hz
ENVIRONMENTAL
Operating Temperature: -10 to 50°C (14°C to 122° F)
Storage Temperature: -40°C to 80°C (-40°C to 176°F)
Humidity: 95%±5% max., (non-condensing)
Altitude: Up to 15,000 feet (4572 m)
FORM FACTOR
Dimensions: 10.5 x 8.5 x 3.2 inches
Weight: 5 lb (2 kg)
STANDARD ACCESSORIES
The Site Analyzer. includes Carrying Case, Instruction
Manual, Serial Cable, PC Tool Software for Windows,
AC Power Supply and Automotive Power Adapter.
BEC MODELNUMBER DESCRIPTION
SA-2500A SITE ANALYZER,780-2500MHZ
CAL-MN-A CALIBRATION COMBO, (M)N
CAL-FN-A CALIBRATION COMBO, (F)N
CAL-ME-A CALIBRATION COMBO, (M)7/16
CAL-FE-A CALIBRATION COMBO, (F)7/16
5010 DIGITAL POWER SENSOR
*DPM ELEMENTS ELEMENTS FOR DIGITAL POWER SENSOR
TC-MNMN-1.5 TEST CABLE, (M)N-(M)N, 1.5M
TC-MNMN-3.0 TEST CABLE, (M)N-(M)N, 3.0M
TC-MNMN-5.0 TEST CABLE, (M)N-(M)N, 5.0M
TC-MNFN-1.5 TEST CABLE, (M)N-(F)N, 1.5M
TC-MNFN-3.0 TEST CABLE, (M)N-(F)N, 3.0M
TC-MNFN-5.0 TEST CABLE, (M)N-(F)N, 5.0M
TC-MNFE-1.5 TEST CABLE, (M)N-(F)7/16, 1.5M
TC-MNFE-3.0 TEST CABLE, (M)N-(F)7/16, 3.0M
TC-MNFE-5.0 TEST CABLE, (M)N-(F)7/16, 5.0M
PA-MNME ADAPTER, (M)N-(M)7/16
PA-FNME ADAPTER, (F)N-(M)7/16
PA-MNFE ADAPTER, (M)N-(F)7/16
PA-FNFE ADAP TER, (F)N-(F)7/16
7002B870 TRANSIT CASE, SITE ANALYZER
SA-BATPAK BATTERY PACK, EXTERNAL
COMPATIBLE PRODUCTS
Model 5010 Digital Power Sensor and *DPM Elements |
|
|
|